damp and dry areas have to be separated.
High-grade, specially formulated polyamide 6,thread made of
nickel-plated brass,the sealing insert are made from flame retarded TPE
Very high impact resistance
With integrated strain relief and optimal ingress protection at the cable
Tested according to EN45545-3
Easy push-in assembly for maximum installation reliability
Screwdriver required for dismantling,
impeding unauthorised or accidental opening
Space-saving dismantling
Excellent conduit pull-out strength
Fits both conduit profiles-fine (T) and coarse (G)
Temperature range: -50°C to+105°C; Short-term: +130°C
Fire barrier classification:
EN 45545-3: E20 Horizontal
E30 Vertical
For technical specification in details, please ask for “Technical Data Sheet” DB-Nr.35400